Power (3ph, Phasor)

Compute three-phase active and reactive powers using three-phase voltage and current phasors

Library

Control and Measurements/Measurements

Description

The Power (3ph, Phasor) block outputs total active power P and reactive power Q of a three-phase voltage-current phasor signal pair. P and Q are computed as follows:

Ia*, Ib*, Ic* are the complex conjugates of Ia, Ib, and Ic.

The figure shows sign conventions:

Dialog Box and Parameters

The block has no parameters.

Inputs and Outputs

Vabc

The three-phase phasor (three complex signals) voltage signal, in volts peak.

Iabc

The three-phase phasor (three complex signals) current signal, in amperes peak.

P

Returns the total active power, in watts.

Q

Returns the total active power, in vars.

Characteristics

Direct FeedthroughYes
DimensionalizedNo

Example

The power_PhasorPowerMeasurementspower_PhasorPowerMeasurements example shows the use of the Power (3ph, Phasor) block.